ASTM D5469-00

system ASTM 2017-08-16 15 PDF 413 0 2026-07-03 23:23
summary
Standard Guide for Application of New Spray Applied Polyurethane Foam and Coated Roofing Systems
description

Scope

1.1 This guide covers the application of new roofing systems consisting of spray applied polyurethane foam insulation, elastomeric protective coatings, and optional mineral granules. This guide does not apply to retrofit or remedial applications.

1.2 Design criteria associated with the installation of spray in place polyurethane foam are beyond the scope of this specification.

1.3 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only.

1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Details
Publisher ASTM
File size 373.75 KB
Pages 7
Format PDF
Publication date 2017-08-16