Significance and Use
5.1 The pour point of a petroleum product is an index of the lowest temperature of its utility for certain applications. Flow characteristics, like pour point, can be critical for the correct operation of lubricating oil systems, fuel systems, and pipeline operations.
5.5 This test method yields a pour point in a format similar to Test Method D97/IP15 when the 3°C interval results are reported.
Scope
1.1 This test method covers the determination of pour point of petroleum products by an automatic instrument that tilts the test jar during cooling and detects movement of the surface of the test specimen with an optical device.
1.2 This test method is designed to cover the range of temperatures from −66 to +51°C; however, the range of temperatures included in the 1992 interlaboratory test program only covered the temperature range from −39 to +6°C, and the range of temperatures included in the 1998 interlaboratory test program was −51 to −11°C. (See Section 13.)
1.4 This test method is not intended for use with crude oils.