loading preview...
summary
Testing concrete. Method for determination of density of partially compacted semi-dry fresh concrete | Status: Current, Confirmed
description
1 Scope
This part of this British Standard contains the method by which the density of semi-dry, partially compacted concrete can be obtained for the purpose of determining the quantity of materials necessary to generate a volume of 1 cubic metre, also known as the “yield”. The method applies to plain concrete made with aggregate having a nominal maximum aggregate size, Dmax of 40 mm or less but not to concrete with a slump of more than 10 mm when tested in accordance with BS EN 12350‑2.
NOTE 1 The method for the determination of density of concrete with a slump of more than 10 mm is described in BS EN 12350‑6.
NOTE 2 This method is not applicable to concrete designed to conform to the requirements of the Specification for Highway Works [1] which describes a specific method for to be applied to hydraulically bound materials intended for use in highway pavements.
Details
Publisher
BS
File size
720.24 KB
Pages
16
Format
PDF
Publication date
2011-08-31
ISBN-13
978-0-580-74628-4
ISBN-13 plain
9780580746284
ISBN-10
0580746284