loading preview...
summary
Automatic electrostatic application systems for ignitable liquid coating materials. Safety requirements. | Status: Current
description
1 Scope
1.1 This document specifies the electrical requirements for the design of automatic electrostatic application systems for liquid coating materials which can be ignited in an atomised state, used within a temperature range from 5 °C to 40 °C.
This document considers automatic electrostatic application systems for processing ignitable liquid coating materials, where the conductivity of the complete system is limited up to 50 nS/cm. Together with additional measures like e.g. potential separation systems, these requirements can also be applied to ignitable liquid coating materials, where the conductivity of the complete system is limited up to 2 000 μS/cm.
Ignition hazards related to the generated explosive atmosphere and the protection of persons against electric shock are considered.
Details
Publisher
BS
File size
3.93 MB
Pages
60
Format
PDF
Publication date
2025-03-10
ISBN-13
978-0-539-14185-6
ISBN-13 plain
9780539141856
ISBN-10
0539141856