Switches for household and similar fixed electrical installations. Collateral standard. Switches and related accessories for use in home and building electronic systems (HBES). | Status: Superseded, Withdrawn
description
1 Scope
This clause of Part 2-1 is replaced by the following:
This collateral standard applies to HBES switches with a working voltage not exceeding 250 V a.c. and a rated current up to and including 16 A. for household and similar fixed electrical installations either indoors or outdoors and to associated electronic extension units.
It applies
- - to HBES switches for the operation of lamp circuits and the control of the brightness of lamps (dimmers) as well as the control of the speed of motors (e.g. those used in ventilating fans) and for other purposes (e.g. heating installations),
- - to sensors, actuators, switched-socket-outlets, associated electronic extension units, etc
- - intentionally by a person via an actuating member, a key, a card, etc., via a sensing surface or a sensing unit, by means of touch, proximity, turn, optical, acoustic, thermal,
- - by physical means, e.g. light, temperature, humidity, time, wind velocity, presence of people,
- - by any other influence;
- - by an electronic signal via several media, e.g. powerline (mains), twisted pair, optical fibre, radio frequency, infra-red, etc…
NOTE 1 This annex is not intended to cover devices falling within the scope of IEC 60730.
NOTE 2 Electronic switches without a mechanical switch in the main circuit do not provide a "full off-state". Therefore, the circuit on the load side should be considered to be live.