Electrical supply track systems for luminaires. | Status: Current
description
1 Scope
This International Standard applies to the following track systems with two or more poles for the connection of luminaires to the electrical supply consisting of, either
- – a system with a rated voltage not exceeding 440 V between poles (live conductors) with provision for earthing (class I) and a rated current not exceeding 16 A per conductor, or
- – a SELV system without provision for protective earthing (class III) and a rated current not exceeding 25 A per conductor, or
- – a combination of the two systems mentioned above (mixed supply system) for the connection of both mains voltage luminaires (class I or II) and SELV supplied luminaires (class III) simultaneously, but in different sector openings (mains or SELV).
NOTE 1 At present, the following types of control systems are available on the market:
- - control signal, with basic insulation to LV supply (e.g. digital addressable lighting interface, 1 V to 10 V DC signal);
- - control signal, SELV/PELV insulated to LV supply (e.g. dmX);
- - control signal, not insulated to LV supply (e.g. push button control/phase cut/step dim).
NOTE 2 Requirements for PELV are under consideration, pending modification in IEC 60598‑1.