loading preview...
summary
Electromagnetic compatibility (EMC). Generic standards. Emission standard for residential, commercial and light-industrial environments | Status: Superseded, Withdrawn
description
1 Scope and object
This part of IEC 61000 for EMC emission requirements applies to electrical and electronic apparatus intended for use in residential, commercial and light-industrial environments.
Emission requirements in the frequency range 0 Hz to 400 GHz are covered. No measurement needs to be performed at frequencies where no requirement is specified.
This generic EMC emission standard is applicable if no relevant dedicated product or product- family EMC emission standard exists.
This standard applies to apparatus intended to be directly connected to a low-voltage public mains network or connected to a dedicated DC source, which is intended to interface between the apparatus and the low-voltage public mains network. This standard applies also to apparatus which is battery operated or is powered by a non-public, but non-industrial, low- voltage power distribution system if this apparatus is intended to be used in the locations described below.
The environments encompassed by this standard are residential, commercial and light- industrial locations, both indoor and outdoor. The following list, although not comprehensive, gives an indication of locations that are included:
- – residential properties, for example houses, apartments;
- – retail outlets, for example shops, supermarkets;
- – business premises, for example offices, banks;
- – areas of public entertainment, for example cinemas, public bars, dance halls;
- – outdoor locations, for example petrol stations, car parks, amusement and sports centres;
- – light-industrial locations, for example workshops, laboratories, service centres.
NOTE 1 Safety considerations are not covered by this standard.
NOTE 2 In special cases, situations will arise where the levels specified in this standard will not offer adequate protection; for example where a sensitive receiver is used in close proximity to an apparatus. In these instances, special mitigation measures may have to be employed.
NOTE 3 As the requirements in this standard are more stringent than the requirements in IEC 61000‑6‑4, equipment fulfilling the requirements of this standard will also comply with the requirements of IEC 61000‑6‑4.
Details
Publisher
BS
File size
1.62 MB
Pages
24
Format
PDF
Publication date
2007-02-28
ISBN-13
978-0-580-80428-1
ISBN-13 plain
9780580804281
ISBN-10
0580804281