loading preview...
summary
Metallic communication cable test methods. Electromagnetic compatibility (EMC). Test method for measuring of transfer impedance ZT and screening attenuation as or coupling attenuation ac of connectors and assemblies up to and above 3 GHz. Triaxial tube in tube method | Status: Superseded, Withdrawn
description
1 Scope
This triaxial method is suitable to determine the surface transfer impedance and/or screening attenuation and coupling attenuation of mated screened connectors (including the connection between cable and connector) and cable assemblies. This method could also be extended to determine the transfer impedance, coupling or screening attenuation of balanced or multipin connectors and multicore cable assemblies. For the measurement of transfer impedance and screening- or coupling attenuation, only one test set-up is needed.
Details
Publisher
BS
File size
2.23 MB
Pages
50
Format
PDF
Publication date
2016-03-31
ISBN-13
978-0-580-95847-2
ISBN-13 plain
9780580958472
ISBN-10
0580958472