High-voltage switchgear and controlgear. Alternating current contactors, contactor-based controllers and motor-starters | Status: Superseded, Withdrawn
description
1 General
1.1 Scope and object
This part of IEC 62271 is applicable to a.c. contactors and/or contactor-based controllers and motor-starters designed for indoor installation and operation at frequencies up to and including 60 Hz on systems having voltages above 1 000 V but not exceeding 24 000 V. It is applicable only to three-pole devices for use in three-phase systems, and single-pole devices for use in single-phase systems. Two-pole contactors and starters for use in single-phase systems are subject to agreement between manufacturer and user. Contactors and/or starters dealt with in this standard typically do not have adequate short-circuit interruption capability. In this context, this standard gives requirements for- — motor starters associated with separate short-circuit protective devices;
- — controllers - contactors combined with short-circuit protective devices (SCPD).
- — direct-on-line starters;
- — reversing starters;
- — two-direction starters;
-
— reduced kVA (voltage) starters;
- • auto-transformer starters;
- • rheostatic starters;
- • reactor starters.
- — circuit-breaker-based motor-starters;
- — single-pole operation of multi-pole contactors or starters;
- — two-step auto-transformer starters designed for continuous operation in the starting position;
- — unbalanced rheostatic rotor starters, i.e. where the resistances do not have the same value in all phases;
- — equipment designed not only for starting, but also for adjustment of speed;
- — liquid starters and those of the "liquid-vapour" type;
- — semiconductor contactors and starters making use of semiconductor contactors in the main circuit;
- — rheostatic stator starters;
- — contactors or starters designed for special applications.
NOTE 1 Thermal electrical relays are covered by IEC 60255‑8.
NOTE 2 High-voltage current-limiting fuses are covered by IEC 60282‑1 and IEC 60644.
NOTE 3 Metal-enclosed switchgear and controlgear for rated voltages above 1 kV and up to and including 52 kV are covered by IEC 62271‑200.
NOTE 4 Disconnectors and earthing switches are covered by IEC 62271‑102.
NOTE 5 High-voltage switches above 1 kV and less than 52 kV are covered by IEC 62271‑1031.
The object of this standard is to state- a) the characteristics of contactors and starters and associated equipment;
-
b) the conditions with which contactors or starters shall comply with reference to:
- 1) their operation and behaviour,
- 2) their dielectric properties,
- 3) the degrees of protection provided by their enclosures, where applicable,
- 4) their construction,
- 5) for controllers, interactions between the various components, for example SCPD co-ordination;
- c) the tests intended for confirming that these conditions have been met, and the methods to be adopted for these tests;
- d) the information to be given with the equipment or in the manufacturer's literature.