- • has a control pilot function controller in accordance with IEC TS 62763;
- • checks supply conditions and prevents charging in case of supply faults under specified conditions;
- • may have a switched protective conductor.
NOTE 1 In Denmark, the following additional requirement applies: for IC-CPDs supplied with a plug for household and similar use the maximum charging current is 8 A, if the charging cycle can exceed 2 h.
NOTE 2 In Finland, the following additional requirement applies: for IC-CPDs supplied with a plug for household and similar use the maximum charging current is 8 A for long lasting charging.
This standard is applicable to IC-CPDs to be used in a.c. circuits only, with preferred values of rated frequency 50 Hz, 60 Hz or 50/60 Hz. IC-CPDs according to this standard are not intended to be used to supply electric energy towards the connected grid. This standard is applicable to IC-CPDs having a rated residual operating current not exceeding 30 mA and are intended to provide additional protection for the circuit downstream of the IC-CPD in situations where it cannot be guaranteed that the installation is equipped with an RCD with I∆n ≤ 30 mA. The IC-CPD consists of:- • a plug for connection to a socket-outlet in the fixed installation;
- • one or more subassemblies containing the control and protection features;
- • a cable between the plug and the subassemblies (optional);
- • a cable between the subassemblies and the vehicle connector (optional);
- • a vehicle connector for connection to the electric vehicle.
NOTE 3 In Denmark: the requirements in this standard cannot replace or change any part of the Danish National requirements for plugs for household and similar use according to DS 60884-2-D1.
Plugs, connectors and cables which are part of the IC-CPD are not tested according to this standard. These parts are tested separately according to their specific product standard.NOTE 4 In the following countries, requirements for EV (mode 2) Cord Sets are covered by NMX-J 677-ANCE-2013/ CSA C22.2 No. 280-13/ UL 2594: Standard for Electric Vehicle Supply Equipment: US, CA, MX.
The switching contacts of the IC-CPD are not required to provide isolation, as isolation can be ensured by disconnecting the plug. The IC-CPD may have a non-replaceable integral fuse in the phase(s) and/or neutral current path.