loading preview...
summary
Environmental testing. Tests. Test Fx: Vibration. Multi-exciter and multi-axis method | Status: Current
description
1 Scope
This document provides a test procedure for use with multi-exciter and multi-axis vibration test systems. The vibration test is intended for general application to components, equipment, and other products, hereinafter referred to as "specimens", subjected to dynamic environments that could arise during an equipment life cycle. Although this document is mainly intended for vibration testing, the procedure is also applied to certain types of shock and transient tests.
The test procedure set out in this document is applicable where a specimen is required to demonstrate its adequacy to resist specified vibration, shock and transient conditions, without unacceptable degradation of functional or structural performance. The test procedure has significant similarity to test procedures of other IEC 60068‑2 documents and encompasses the same range of vibration and shock excitation types.
This document is applicable to specimens subjected to vibration, shock and transient conditions resulting from transportation and/or operational environments, for example in aircraft, space vehicles and land vehicles. It is primarily intended for unpackaged specimens. It is applicable to specimens in their transportation container when the latter are considered as part of the specimen itself.
The test method and associated techniques addressed within this document are primarily intended for use with multiple electrodynamic or servo-hydraulic vibration generators along with an associated computer-based digital control system to control of the specimen excitations.
This document encompasses two testing approaches, commonly referred to as multi-exciter single-axis (MESA), and multi-exciter multi-axis (MEMA). These are:
- a) Utilising fixed base shakers either in a single axis or a selected combination of fixed X, Y, Z configurations, also allowing for rotations dependent upon fixture coupling design.
- b) Utilising multiple shakers attached directly to the specimen via flexible couplings or similar methods. Here the shakers are attached at any point and in any direction on the specimen. This approach is quite similar to that used for modal testing, but using environmental test severities.
Details
Publisher
BS
File size
1.27 MB
Pages
44
Format
PDF
Publication date
2024-03-26
ISBN-13
978-0-539-15254-8
ISBN-13 plain
9780539152548
ISBN-10
0539152548