loading preview...
summary
Electrical relays. Tests and measurements. Internal moisture | Status: Current
description
1 Scope
This document is used for testing electromechanical elementary relays (electromechanical relays, reed relays, reed contacts, reed switches and technology combinations of these) and evaluates their ability to perform under expected conditions of transportation, storage, and all aspects of operational use.
This document defines a standard test method to provoke internal moisture inside relays by different methods. The device under test (DUT) is tested at its specified energization values throughout the defined temperature range.
The test methods in this document are applicable to RT III, RT IV and RT V products only, i.e., wash-tight, sealed, and hermetically sealed DUTs.
Details
Publisher
BS
File size
835.09 KB
Pages
14
Format
PDF
Publication date
2025-03-28
ISBN-13
978-0-539-20398-1
ISBN-13 plain
9780539203981
ISBN-10
0539203981