loading preview...
summary
Water meters for cold potable water and hot water. Non-metrological requirements not covered in ISO 4064-1 | Status: Current
description
1 Scope
This document applies to water meters used to meter the volume of cold potable water and hot water flowing through a fully charged, closed conduit. These water meters incorporate devices which indicate the integrated volume.
This document specifies technical characteristics and pressure loss requirements for meters for cold potable water and hot water. It applies to water meters which can withstand:
- a) a maximum admissible pressure (MAP) equal to at least 1 MPa1 [0,6 MPa for meters for use with pipe nominal diameters (DNs) ≥500 mm];
- b) a maximum admissible temperature (MAT) for cold potable water meters of 30 °C;
- c) a MAT for hot water meters of up to 180 °C, depending on class.
Details
Publisher
BS
File size
1.53 MB
Pages
36
Format
PDF
Publication date
2025-01-15
ISBN-13
978-0-539-25311-5
ISBN-13 plain
9780539253115
ISBN-10
0539253115