1 Scope
This document specifies a method to measure the solar heat gain coefficient of complete windows and doors.
This document applies to windows and doors
- a) with various types of glazing (glass or plastic; single or multiple glazing; with or without low emissivity coatings, and with spaces filled with air or other gases),
- b) with opaque panels,
- c) with various types of frames (wood, plastic, metallic with and without thermal barrier or any combination of materials),
- d) with various types of shading devices (blind, screen, film or any attachment with shading effects),
- e) with various types of active solar fenestration systems [building-integrated PV systems (BIPV) or building-integrated solar thermal collectors (BIST)].
- a) shading effects of building elements (e.g. eaves, sleeve wall, etc.);
- b) heat transfer caused by air leakage between indoors and outdoors;
- c) ventilation of air spaces in double and coupled windows;
- d) thermal bridge effects at the rebate or joint between the window or door frame and the rest of the building envelope.
- a) non-vertical windows;
- b) curtain walls;
- c) industrial, commercial and garage doors.