loading preview...
summary
Non-destructive testing. Methods for absolute calibration of acoustic emission transducers by the reciprocity technique. | Status: Current
description
1 Scope
This Technical Report describes the method of three-transducer calibration for calibrating frequency responses of absolute sensitivity by means of a reciprocity technique using three reversible acoustic emission transducers of the same kind, the method of two-transducer calibration for calibrating frequency responses of reception sensitivity of an optional acoustic emission transducer by using one acoustic emission transducer, the transmission responses of which have been calibrated by three-transducer calibration, the method for impulse response calibration for calibrating impulse responses of absolute sensitivity through inverse Fourier transform of the frequency responses measured by the three-transducer calibration, and the method for representing the calibration results.
Details
Publisher
BS
File size
1.6 MB
Pages
28
Format
PDF
Publication date
2012-02-29
ISBN-13
978-0-580-70487-1
ISBN-13 plain
9780580704871
ISBN-10
0580704871